First time here? Checkout the FAQ!
x
0 votes
by (1.3k points)
retagged by
Is it possible to use the total ionic current as a parameter (for a channel current for example) when writing a model in easyML? If yes, how? If not, is there a workaround when compiling from source or can it be included in openCARP by default?

1 Answer

0 votes
by (3.6k points)
Hi Teo,

As Iion is a protected word in EasyML. A possible solution could be adding a parameter that would modify Iion. For example, you can create a parameter called factorcurrent=1;.param(); and when you have Iion, you can use the created variable to multiply Iion (Iion = factor current*(INa+...).

I hope this can help in your simulations.

Best,

Jorge
Welcome to openCARP Q&A. Ask questions and receive answers from other members of the community. For best support, please use appropriate TAGS!
architecture, carputils, documentation, experiments, installation-containers-packages, limpet, slimfem, website, governance
...